Product Category
Contact us
  • Phone

    021-59919806

  • Address

    No.1-42, Lane 83, Hongxiang North Road, Wanxiang Town, Pudong New Area, Shanghai Building 83,No42,hongxiang bei Rd,Pudong district,shanghai,China

  • Email

    lifengndt@yeah.net

FPI-500 Semi-automatic Fluorescent Penetration Inspection Line

Inquiry

1. Overview

The groove type fluorescent penetrant is the most traditional form of detection in the industry, but it can ensure that the penetrant on the surface of the detected workpiece is fully covered, and the form of a material frame is used to carry the workpiece. If the operation type permeate is unreasonably designed, it will cause more liquid to be carried out, increase the consumption of permeate, and also affect the effect of darkroom observation and cleaning effect, and the waste water will also double, resulting in an increase in the cost of fluorescent waste water treatment equipment.

Reasonable penetrant inspection line design can not only ensure the stability and reliability of the effect, but also effectively control the production cost

2.FiNDT Design Advantages

2.1The electrical control cabinet adopts the man-machine interface control design to meet the requirements of different testing processes and production takt;

2.2.The drying box adopts the nine-point uniform temperature method, and the temperature control accuracy of each point can reach +-3℃, which fully meets the ASTME1417 standard.

2.3.The default dry powder imaging ensures that the workpiece is fully covered by the imaging powder. Wet powder imaging can also be designed according to user needs.

2.4Combination of trough process and automatic control.

2.5The inside and outside are made of high-quality stainless steel to ensure that the workpiece is not corroded, and the floor area can be designed according to the user's on-site layout.

2.6.Scope of application: workpieces of any shape. 